APPENDIX
A
All of the test and inspections
listed on the STRUCTURAL TESTS AND INSPECTION SCHEDULE will be
called for at one time or another in the plans and specifications
submitted to a Building Department. Seldom will one project require
all of the tests and inspections shown. The listed items fall
into one or the following categories:
- Required by plans and specifications
as deemed necessary by the Architect/Engineer for the integrity
and successful performance of the project.
- Required by specific reference
in the Uniform Building Code, 1997 Edition.
- A combination of 1 and 2
The following lists the Building
Code references which bear on each of the tests and inspections
in the STRUCTURAL TESTS AND INSPECTION SCHEDULE. Where no Building
Code Section is cited, the test or inspection is optional at
the discretion of the Architect/Engineer.
-
- REINFORCING STEEL
- Tensile and Bend Test - 1903.1
- Inspection of Placement - 1701.5
(4)
- Inspection of Welding - 1701.5
(5.3)
-
- MASONRY
- Preliminary Tests (Masonry Units,
Wall Prisms) - 2105.3 (2), STDS Chapter 21
- Subsequent Tests (Mortar, Grout,
Field Wall Prisms) - 2105.3 (3-5)
- Inspection of Grouting - 2104.6
(1)
- Inspection of Masonry Placement
and Grouting - 1701.5 (7),
- 2104.1-8, 2105.1-5, Table 21A,
Table 24B, Table 21C
-
- CONCRETE, SHOTCRETE, GROUT
& MORTAR
|
Concrete |
Shotcrete |
Grout |
Mortar |
|
|
1903.1 |
1922.3 |
STDS 21.19 |
STDS 21.15 |
Agg. Tests for Design |
|
1903.3 |
|
STDS 21.19 |
STDS 21.15 |
Suitability of Agg. |
|
1905.1 |
1922.2 |
|
|
Mix Designs |
|
|
|
|
|
Test Panel |
|
STDS 26.13 |
|
|
|
Conc. Batch Plant Insp. |
|
|
|
|
|
Cement Grab Sample |
|
1701.5 |
1701.5 |
1701.5 |
1701.5 |
Inspect Placing |
|
1904.6 |
1022.10 |
STDS 21.18 |
STDS 21.17 |
Compression Tests |
|
1905.6 |
1922.10 |
STDS 21.18 |
STDS 21.17 |
Cast Specimens |
|
|
|
|
|
Pick-Up Samples |
|
|
|
|
|
Shrinkage Bars |
|
|
|
|
|
Yield Check |
|
|
|
|
|
Air Content |
|
|
|
|
|
Dry Unit Weight |
-
- PRECAST/POST-TENSIONED CONCRETE
- Reinforcing Tests (see Reinforcing
Steel)
- Inspection of Reinforcing Placement
- 1701.5 (4)
- Tendon Tests - 1912.14 (3)
- Inspection of Tendon Placement
- 1701.5 (4)
- Inspection of Concrete Placement
- 1701.5 (1)
- Inspection of Concrete Batching
- STDS 19.3
- Inspection of Panel Attach.
and Inserts - 1701.5 (1)
- Inspection of Panel Installation
- 1701.5 (1)
- Compression Tests - 1905.6
- Inspection of Stressing - 1701.5
(4)
-
- PILING, CAISSONS, CAPS, TIES
- Inspection of Reinforcing Placement
- 1701.5 (4)
- Inspection of Concrete Placement
- 1701.5 (1)
- Inspection of Concrete Building
- STDS 19.3
-
- UNDERPINNING
- Inspection of Steel Fabrication
- 1701.5 (5)
- Inspection of Reinforcing and
Forms - 1701.5 (4)
- Inspection of Concrete Placement
- 1701. 5 (1)
-
- STRUCTURAL STEEL
- Shop Identification and Welding
-1701.5 (5), 2202.2, Chapter 22
- Shopt U.T. - 1703
- Shop R.T. - 1703
- Field Welding - 1701.5 (5),
Chapter 22
- Field Bolting - 1701.5 (5),
Chapter 22
- Field U.T. - 1703
- Field R.T. - 1703
- Metal Deck Welding - 1701.5
(5)
-
- STRUCTURAL WOOD
- Inspection of Fabrication -
ANSI/AITC 190.1
- Sample and Test Components -
ANSI/AITC 190.1
- Shear Diaphragms - 1600
-
-
- home - who we are - guidelines for
special inspection - structural tests
and inspection schedule - meeting
schedule
-
Please send your comments