APPENDIX A

All of the test and inspections listed on the STRUCTURAL TESTS AND INSPECTION SCHEDULE will be called for at one time or another in the plans and specifications submitted to a Building Department. Seldom will one project require all of the tests and inspections shown. The listed items fall into one or the following categories:

    1. Required by plans and specifications as deemed necessary by the Architect/Engineer for the integrity and successful performance of the project.
    2. Required by specific reference in the Uniform Building Code, 1997 Edition.
    3. A combination of 1 and 2

 

The following lists the Building Code references which bear on each of the tests and inspections in the STRUCTURAL TESTS AND INSPECTION SCHEDULE. Where no Building Code Section is cited, the test or inspection is optional at the discretion of the Architect/Engineer.

 
REINFORCING STEEL
Tensile and Bend Test - 1903.1
Inspection of Placement - 1701.5 (4)
Inspection of Welding - 1701.5 (5.3)
 
MASONRY
Preliminary Tests (Masonry Units, Wall Prisms) - 2105.3 (2), STDS Chapter 21
Subsequent Tests (Mortar, Grout, Field Wall Prisms) - 2105.3 (3-5)
Inspection of Grouting - 2104.6 (1)
Inspection of Masonry Placement and Grouting - 1701.5 (7),
2104.1-8, 2105.1-5, Table 21A, Table 24B, Table 21C
 
CONCRETE, SHOTCRETE, GROUT & MORTAR
Concrete  Shotcrete Grout Mortar  
1903.1 1922.3 STDS 21.19 STDS 21.15 Agg. Tests for Design
1903.3   STDS 21.19 STDS 21.15 Suitability of Agg.
1905.1 1922.2     Mix Designs
        Test Panel
STDS 26.13       Conc. Batch Plant Insp.
        Cement Grab Sample
1701.5 1701.5 1701.5 1701.5 Inspect Placing
1904.6 1022.10 STDS 21.18 STDS 21.17 Compression Tests
1905.6 1922.10 STDS 21.18 STDS 21.17 Cast Specimens
        Pick-Up Samples
        Shrinkage Bars
        Yield Check
        Air Content
        Dry Unit Weight
 
PRECAST/POST-TENSIONED CONCRETE
Reinforcing Tests (see Reinforcing Steel)
Inspection of Reinforcing Placement - 1701.5 (4)
Tendon Tests - 1912.14 (3)
Inspection of Tendon Placement - 1701.5 (4)
Inspection of Concrete Placement - 1701.5 (1)
Inspection of Concrete Batching - STDS 19.3
Inspection of Panel Attach. and Inserts - 1701.5 (1)
Inspection of Panel Installation - 1701.5 (1)
Compression Tests - 1905.6
Inspection of Stressing - 1701.5 (4)
 
PILING, CAISSONS, CAPS, TIES
Inspection of Reinforcing Placement - 1701.5 (4)
Inspection of Concrete Placement - 1701.5 (1)
Inspection of Concrete Building - STDS 19.3
 
UNDERPINNING
Inspection of Steel Fabrication - 1701.5 (5)
Inspection of Reinforcing and Forms - 1701.5 (4)
Inspection of Concrete Placement - 1701. 5 (1)
 
STRUCTURAL STEEL
Shop Identification and Welding -1701.5 (5), 2202.2, Chapter 22
Shopt U.T. - 1703
Shop R.T. - 1703
Field Welding - 1701.5 (5), Chapter 22
Field Bolting - 1701.5 (5), Chapter 22
Field U.T. - 1703
Field R.T. - 1703
Metal Deck Welding - 1701.5 (5)
 
STRUCTURAL WOOD
Inspection of Fabrication - ANSI/AITC 190.1
Sample and Test Components - ANSI/AITC 190.1
Shear Diaphragms - 1600
 
 

home - who we are - guidelines for special inspection - structural tests and inspection schedule - meeting schedule